Схема узла
Запчасти для посудомоечной машины Whirlpool ADP 7990 IXM
Выберите версию/индустриальный код: * От выбранной версии зависит совместимость запчастей
854299061740
Характеристики:
Water pressure: Inlet pressure | 0.3 bar - 10 bar |
Rotations: Drain pump motor | 3000 RPM |
Detergent capacity: Rinse aid dosage | 135 cm 3 |
Electronic boards: Serial boards (Data set) | 739792 |
Flow rates/ Inlet volume: Shower/Spray arm top | ~ 8 l/min |
Dimensions + Weight: Decor plate for Free standing appliances with flat/ square outer door (Weight) | max. 1.8 kg |
Heating element: Temperature on surface | ~ 115 °C |
Flow rates/ Inlet volume: Fan for drying | Total 900 l/min Primary air flow 210 l/min Secondary air flow 780 l/min |
Water softener setting | To change the water softener setting:· Push the POWER button on · Change to program 2 · Hold the START button for 5 seconds until the LED is flashing · is shown by flashing LED or digital display · By pushing the START button you can change the setting · Push the POWER button off to save and exit the water softener setting |
Detergent capacity: Prewash | 10 cm 3 |
Drain pump motor: Power Consumption | 30 W |
Coil of dispenser: Resistance | 1.3 k Ω |
Flow rates/ Inlet volume: Spray pump | 45 l/min - 65 l/min |
Program information: | All programs will be locked after start. Changing the program or ?nishing the program will be possible only after pressing the start button for longer then 1.5 sec. (Break by customer) A switching off the appliance or unplug the appliance for a while, this will frozen the program step and later on, the program continuos on the same position. Exception: Switching off the appliance or unplug the appliance during the drying phase, this will lead directly to the end of the program. |
Spray arms, turning rhythm at alternating spray system: Intermediate rinse | Spray arm lower ~2min Upper arm ~2min |
Электрические базовые данные: напряжение | 220/ 240 V |
Spray pump motor alternating spray system: Capacitor | 4 µ F |
Heating element: Safety thermostat self reset (Temperature of water) | ~ 85 °C |
Rotations: Spray pump motor | 2800 RPM |
Motor Diverter Valve: Signal (2x within ~13 sec.) | 5.0 V |
Heating element: | 1 Element system |
Electronic boards: Serial boards (Basic UCB, not programmed) | 4619 727 21531 |
Single electric water inlet valve: Resistance | 3.76 k Ω |
Data Energy Label: Drying Performance | A |
Single electric water inlet valve: Voltage | 220/ 240 V |
Heating element: Power Consumption | 1.87/ 2.04 kW |
Regeneration valve: Frequency | 50/ 60 Hz |
Rotations: Spray arm upper | 30 RPM - 40 RPM |
Flow rates/ Inlet volume: Pump height max. | 1.1 m |
Flow rates/ Inlet volume: Spray arm lower | ~ 33 l/min |
Water softener: Resin container | 700 cm 3 |
Motor Diverter Valve: Voltage | 220 V - 240 V |
Electronic boards: Serial boards (UB) | 4619 724 86781 DB 4619 727 24641 |
Heating element: Voltage | 220/ 240 V |
Flow rates/ Inlet volume: Inlet valve | 4 l/min |
Accessory: | If you need spare parts apart from the spare part list have a look in the Service Bulletin 4812 718 40084. For higher mounted Dishwashers to prevent the drain off effect - also usable for lower drain pipes and to prevent the failure F8 use Kit 4812 310 18993. |
Fan for drying: Resistance | 141 Ω |
Water softener: Salt container | 2 kg |
Options: | Zone washing Delay function |
Electronic boards: Serial boards (CB programmed) | 739802 |
Regeneration: Volume | 300 cm 3 |
Drain pump motor: Voltage | 220/ 240 V |
Spray arms, turning rhythm at alternating spray system: Final rinse | Spray arm lower ~2min Upper arm ~2min |
Dimensions + Weight: Decor plate for Free standing appliances with flat/ square outer door (Width) | 583 mm |
Detergent capacity: Dosage steps | 1 ml - 6 ml |
Electrical base data: Total power | 2.0 kW - 2.2 kW |
Coil of dispenser: Frequency | 50/ 60 Hz |
Spray pump motor alternating spray system: Power Consumption | 125 W |
Regeneration: after wash cycles | Depending on the water hardness |
Dimensions + Weight: Product dimensions (Weight) | 58 kg |
Water hardness: Water hardness German degrees °dH French degrees °fH English degrees Clarke °e mmol/l Water softener setting is shown by flashing LED (1x-7x) | 1 soft 0 - 5 0 - 9 0 - 6,3 0 - 0.9 1 x 1 - 2 soft/ medium 6 - 10 10 - 18 7 - 12.6 1 - 1.8 2 x 2 medium 11 - 15 19 - 27 13.3 - 18.9 1.9 - 2.7 3 x 3 medium/ hard 16 - 21 28 - 37 19.6 - 25.9 2.8 - 3.7 4 x (DEFAULT SETTING) 4 hard 22 - 28 38 - 50 26.6 - 35 3.8 - 5.0 5 x 4 very hard 29 - 35 51 - 63 35.7 - 44.1 5.1 - 6.3 6 x 4 extremely hard 36 - 60 (53) 64 - 107 44.8 - 74.9 6.4 - 10.7 7 x |
Optical water indicator (OWI): Combination part of | Turbidity sensor (DON) Thermostat temp. sensor (notice NTC) |
Flow rates/ Inlet volume: Spray arm upper | ~ 27 l/min |
Heating element: Fuse | 206 °C |
Motor Diverter Valve: Frequency | 50/ 60 Hz |
Regeneration valve: Resistance | 3.13 k Ω |
Electronic boards: Serial boards () | Programing of version and programmed control board, see "Service" and "Data set" on rating plate of inner door: |
Data Energy Label: Energy Performance | A |
Flow rates/ Inlet volume: Flow meter | 208 lmp/l |
Data Energy Label: Reference program | A12b |
Размеры + Вес: Размеры продукта (ширина) | 59.7 cm |
Drain pump motor: Resistance | 146 Ω |
Succession of programs: Programs () | see program diagram |
Spray pump motor alternating spray system: HI | 79 Ω |
Электрические базовые данные: частота | 50 Hz |
Spray arms, turning rhythm at alternating spray system: Prewash | Spray arm lower ~3min Upper arm ~1min |
Coil of dispenser: Voltage | 220/ 240 V |
NTC | 20 °C 58.1 kΩ 25 °C 47.1 kΩ 30 °C 38.2 kΩ 40 °C 25.4 kΩ 50 °C 17.2 kΩ 60 °C 11.8 kΩ 70 °C 8.3 kΩ 80 °C 6 kΩ 85 °C 4 kΩ |
Regeneration: Salt consumption for regeneration | ~ 77 g |
Электрическая база данных: Предохранитель | 10 A |
Spray pump motor alternating spray system: Voltage | 220/ 240 V |
Dimensions + Weight: Decor plate for Free standing appliances with flat/ square outer door (Thickness) | max. 4 mm |
Water pressure: Spray pump pressure | 0.3 bar |
Fan for drying: Voltage | 220 V - 240 V |
Размеры + Вес: Размеры продукта (Глубина) | 61.0 cm |
Spray arms, turning rhythm at alternating spray system: Service Test program | Remark: When switching of the main switch or interrupt the mains during the Test Program runs, then the alternating of the spray arms change in the test program to the rhythm of main wash 5/3 min. After finishing the test program (End LED shines and/or Start LED goes of) must the appliance be switched off. Spray arm lower ~30sec Upper arm ~30sec |
Regeneration valve: Voltage | 220/ 240 V |
Rotations: Fan for drying | 2500 RPM |
Detergent capacity: Main wash | 40 cm 3 |
Spray arms, turning rhythm at alternating spray system: Main wash | Spray arm lower ~3min Upper arm ~5min |
Water softener: Regeneration dosage | 300 cm 3 |
Heating element: Resistance | 24.5 Ω |
Water Volume: Water Volume Level | Regeneration 0.3 l 15 mm Back rinse 3x 1.0 l 60 mm Prewash 3.9 l 120 mm Main wash 3.2 l 118 mm Intermediate rinse 1 3.2 l 118 mm Intermediate rinse 2 3.2 l 118 mm Clear rinse 3.2 l 118 mm Safety/ overflow 8.5 l 141 mm |
Single electric water inlet valve: Frequency | 50/ 60 Hz |
Dimensions + Weight: Decor plate for Free standing appliances with flat/ square outer door (Height) | 595 mm |
Heating element: Heating speed | ~ 2.0 °C/min |
Rotations: Spray arm lower | 30 RPM - 40 RPM |
Spray pump motor alternating spray system: HA | 60 Ω |
Data Energy Label: Cleaning Performance | A |
Regeneration: Water hardness | 0 - 60 (53) °dh 0 - 10.7 mmol/l 0 - 107 °Fh |
Flow rates/ Inlet volume: Drain pump | 16 l/min |
Размеры + Вес: Размеры продукта (Высота) | 85,0 cm ± 1.4 |
Motor Diverter Valve: Resistance | 6.5 k Ω |
Regeneration: Number of cycles with 2 kg salt | ~ 26 |