Схема узла
Запчасти для посудомоечной машины Whirlpool ADG 8970
Характеристики:
Water pressure: Inlet pressure | 0.3 bar - 10 bar |
Rotations: Drain pump motor | 3000 RPM |
Detergent capacity: Rinse aid dosage | 135 cm 3 |
Electronic boards: Serial boards (Data set) | 703675 |
Regeneration: Position 0 | after wash cycles 12 Water hardness 0 - 5 °dh 0 - 0.9 mmol/l 0 - 9 °Fh |
Succession of programs: Succession () | A1a - A2a - A3a - A5e - A8a - A9a - A11a |
Flow rates/ Inlet volume: Shower/Spray arm top | ~ 8 l/min |
Heating element: Temperature on surface | ~ 115 °C |
Potentiometer: Points of meassurement: (Position 2) | 1.0 k Ω |
Flow rates/ Inlet volume: Fan for drying | Total 900 l/min Primary air flow 210 l/min Secondary air flow 780 l/min |
Detergent capacity: Prewash | 10 cm 3 |
Drain pump motor: Power Consumption | 30 W |
Coil of dispenser: Resistance | 1.3 k Ω |
Flow rates/ Inlet volume: Spray pump | 45 l/min - 65 l/min |
Regeneration: Position 5 | after wash cycles 2 Water hardness 29 - 35 °dh 5.1 - 6.3 mmol/l 51 - 63 °Fh |
Program information: | End - Acoustic signal All programs will be locked after start. Changing the program or ?nishing the program will be possible only after pressing the start button for longer then 1.5 sec. (Break by customer) A switching off the appliance or unplug the appliance for a while, this will frozen the program step and later on, the program continuos on the same position. Exception: Switching off the appliance or unplug the appliance during the drying phase, this will lead directly to the end of the program. |
Spray arms, turning rhythm at alternating spray system: Intermediate rinse | Spray arm lower ~2min Upper arm ~2min |
Электрические базовые данные: напряжение | 220/ 230 V |
Spray pump motor alternating spray system: Capacitor | 4 µ F |
Heating element: Safety thermostat self reset (Temperature of water) | ~ 85 °C |
Rotations: Spray pump motor | 2800 RPM |
Motor Diverter Valve: Signal (2x within ~13 sec.) | V 5.0 |
Heating element: | 1 Element system |
Electronic boards: Serial boards (Basic UCB, not programmed) | 4619 724 84451 |
Single electric water inlet valve: Resistance | 3.76 k Ω |
Data Energy Label: Drying Performance | A |
Single electric water inlet valve: Voltage | 220/ 240 V |
Heating element: Power Consumption | 1.87/ 2.04 kW |
Regeneration valve: Frequency | 50/ 60 Hz |
Rotations: Spray arm upper | 30 RPM - 40 RPM |
Flow rates/ Inlet volume: Pump height max. | 1.1 m |
Flow rates/ Inlet volume: Spray arm lower | ~ 33 l/min |
Water softener: Resin container | 900 cm 3 |
Motor Diverter Valve: Voltage | 220 V - 240 V |
Electronic boards: Serial boards (UB) | 4619 727 24822 |
Potentiometer: Points of meassurement: (Position 3) | 1.4 k Ω |
Heating element: Voltage | 220/ 230 V |
Flow rates/ Inlet volume: Inlet valve | 4 l/min |
Accessory: | If you need spare parts apart from the spare part list have a look in the Service Bulletin 4812 718 40084. |
Regeneration: Position 2 | after wash cycles 7 Water hardness 11 - 15 °dh 1.9 - 2.7 mmol/l 19 - 27 °Fh |
Fan for drying: Resistance | 141 Ω |
Water softener: Salt container | 2 kg |
Potentiometer: Points of meassurement: (Position 0) | 0.0 k Ω |
Options: | Delay function Sani rinse program |
Electronic boards: Serial boards (CB programmed) | 703685 |
Regeneration: Volume | 300 cm 3 |
Drain pump motor: Voltage | 220/ 240 V |
Regeneration: Position 4 | after wash cycles 3 Water hardness 22 - 28 °dh 3.8 - 5.0 mmol/l 38 - 50 °Fh |
Spray arms, turning rhythm at alternating spray system: Final rinse | Spray arm lower ~2min Upper arm ~2min |
Detergent capacity: Dosage steps | 1 ml - 6 ml |
Electrical base data: Total power | 2.0 kW - 2.2 kW |
Potentiometer: Points of meassurement: (Position 4) | 1.8 k Ω |
Dimensions + Weight: Wooden door for Full Door appliances (Width) | 592 mm - 595 mm |
Coil of dispenser: Frequency | 50/ 60 Hz |
Spray pump motor alternating spray system: Power Consumption | 125 W |
Dimensions + Weight: Product dimensions (Weight) | 53 kg |
Optical water indicator (OWI): Combination part of | Turbidity sensor (DON) Thermostat temp. sensor (notice NTC) |
Dimensions + Weight: Wooden door for Full Door appliances (Height of plinth) | min. 93 mm |
Flow rates/ Inlet volume: Spray arm upper | ~ 27 l/min |
Heating element: Fuse | 206 °C |
Dimensions + Weight: Wooden door for Full Door appliances (Max. stick out over lower edge of appliance door) | 92 mm |
Motor Diverter Valve: Frequency | 50/ 60 Hz |
Regeneration valve: Resistance | 3.13 k Ω |
Electronic boards: Serial boards () | Programing of version and programmed control board, see "Service" and "Data set" on rating plate of inner door: |
Data Energy Label: Energy Performance | A |
Flow rates/ Inlet volume: Flow meter | 208 lmp/l |
Data Energy Label: Reference program | A5e |
Dimensions + Weight: Wooden door for Full Door appliances (Height) | 620 mm - 718 mm |
Размеры + Вес: Размеры продукта (ширина) | 59.7 cm |
Drain pump motor: Resistance | 146 Ω |
Succession of programs: Programs () | see program diagram |
Potentiometer: Points of meassurement: (Position 5) | 2.3 k Ω |
Spray pump motor alternating spray system: HI | 79 Ω |
Электрические базовые данные: частота | 50 Hz |
Spray arms, turning rhythm at alternating spray system: Prewash | Spray arm lower ~3min Upper arm ~1min |
Coil of dispenser: Voltage | 220/ 240 V |
NTC | 20 °C 58.1 kΩ 25 °C 47.1 kΩ 30 °C 38.2 kΩ 40 °C 25.4 kΩ 50 °C 17.2 kΩ 60 °C 11.8 kΩ 70 °C 8.3 kΩ 80 °C 6 kΩ 85 °C 4 kΩ |
Regeneration: Salt consumption for regeneration | 77 g |
Potentiometer: Points of meassurement: (Position 6) | 2.6 k Ω |
Электрическая база данных: Предохранитель | 10 A |
Spray pump motor alternating spray system: Voltage | 220/ 240 V |
Water pressure: Spray pump pressure | 0.3 bar |
Fan for drying: Voltage | 220 V - 240 V |
Размеры + Вес: Размеры продукта (Глубина) | 55.5 cm |
Regeneration: Position 1 | after wash cycles 10 Water hardness 6 - 10 °dh 1 - 1.8 mmol/l 10 - 18 °Fh |
Spray arms, turning rhythm at alternating spray system: Service Test program | Remark: When switching of the main switch or interrupt the mains during the Test Program runs, then the alternating of the spray arms change in the test program to the rhythm of main wash 5/3 min. After finishing the test program (End LED shines and/or Start LED goes of) must the appliance be switched off. Spray arm lower ~30sec Upper arm ~30sec |
Regeneration valve: Voltage | 220/ 240 V |
Potentiometer: Points of meassurement: (Position 1) | 0.5 k Ω |
Rotations: Fan for drying | 2500 RPM |
Detergent capacity: Main wash | 40 cm 3 |
Spray arms, turning rhythm at alternating spray system: Main wash | Spray arm lower ~3min Upper arm ~5min |
Water softener: Regeneration dosage | 300 cm 3 |
Heating element: Resistance | 24.5 Ω |
Water Volume: Water Volume Level | Regeneration 0.3 l 15 mm Back rinse 3x 1.0 l 60 mm Prewash 3.9 l 120 mm Main wash 3.2 l 118 mm Intermediate rinse 1 3.2 l 118 mm Intermediate rinse 2 3.2 l 118 mm Clear rinse 3.2 l 118 mm Safety/ overflow 8.5 l 141 mm |
Dimensions + Weight: Wooden door for Full Door appliances (Weight) | 2.5 kg - 6.5 kg |
Single electric water inlet valve: Frequency | 50/ 60 Hz |
Heating element: Heating speed | ~ 2.0 °C/min |
Rotations: Spray arm lower | 30 RPM - 40 RPM |
Regeneration: Position 6 | after wash cycles 1 Water hardness 36 - 60 °dh 6.4 - 10.7 mmol/l 64 - 107 °Fh |
Spray pump motor alternating spray system: HA | 60 Ω |
Data Energy Label: Cleaning Performance | A |
Dimensions + Weight: Wooden door for Full Door appliances (Thickness) | 16 mm - 20 mm |
Potentiometer: Points of meassurement: () | 1(black) to 2 (middle) |
Electronic boards: Serial boards (DLB) | 4619 720 92232 |
Flow rates/ Inlet volume: Drain pump | 16 l/min |
Regeneration: Position 3 | after wash cycles 5 Water hardness 16 - 21 °dh 2.8 - 3.7 mmol/l 28.37 °Fh |
Размеры + Вес: Размеры продукта (Высота) | 82.0 cm - 87.0 cm |
Motor Diverter Valve: Resistance | 6.5 k Ω |
Regeneration: Number of cycles with 2 kg salt | 26 |