Название: Запчасть для электропосудомоечной машины Whirlpool 481240448753
Недоступно к заказу
Номер на схеме: 9935
Артикул:482253280216
Название: Воронка Whirlpool 482253280216
Недоступно к заказу
Характеристики:
Water pressure: Inlet pressure
0.3 bar - 10 bar
Rotations: Drain pump motor
3000 RPM
Detergent capacity: Rinse aid dosage
135 cm 3
Electronic boards: Serial boards (Data set)
486991
Regeneration: Position 0
after wash cycles 12
Water hardness 0 - 5 °dh 0 - 0.9 mmol/l 0 - 9 °Fh
Flow rates/ Inlet volume: Shower/Spray arm top
~ 8 l/min
Heating element: Temperature on surface
~ 115 °C
Potentiometer: Points of meassurement: (Position 2)
1.0 k Ω
Flow rates/ Inlet volume: Fan for drying
Total 900 l/min
Primary air flow 210 l/min
Secondary air flow 780 l/min
Detergent capacity: Prewash
10 cm 3
Drain pump motor: Power Consumption
30 W
Coil of dispenser: Resistance
1.3 k Ω
Flow rates/ Inlet volume: Spray pump
45 l/min - 65 l/min
Regeneration: Position 5
after wash cycles 2
Water hardness 29 - 35 °dh 5.1 - 6.3 mmol/l 51 - 63 °Fh
Program information:
All programs will be locked after start. Changing the program or ?nishing the program will be possible only after pressing the start button for longer then 1.5 sec. (Break by customer)
A switching off the appliance or unplug the appliance for a while, this will frozen the program step and later on, the program continuos on the same position.
Exception: Switching off the appliance or unplug the appliance during the drying phase, this will lead directly to the end of the program.
Spray arms, turning rhythm at alternating spray system: Intermediate rinse
Spray arm lower ~2min
Upper arm ~2min
Электрические базовые данные: напряжение
220/ 230 V
Spray pump motor alternating spray system: Capacitor
4 µ F
Heating element: Safety thermostat self reset (Temperature of water)
~ 85 °C
Rotations: Spray pump motor
2800 RPM
Motor Diverter Valve: Signal (2x within ~13 sec.)
5.0
V
Heating element:
1 Element system
Electronic boards: Serial boards (Basic UCB, not programmed)
4619 724 17421
Data Energy Label: Drying Performance
A
Heating element: Power Consumption
1.87/ 2.04 kW
Regeneration valve: Frequency
50/ 60 Hz
Rotations: Spray arm upper
30 RPM - 40 RPM
Flow rates/ Inlet volume: Pump height max.
1.1 m
Flow rates/ Inlet volume: Spray arm lower
~ 33 l/min
Water softener: Resin container
900 cm 3
Motor Diverter Valve: Voltage
220 V - 240 V
Electronic boards: Serial boards (UB)
4619 724 30711 DB 4619 714 31361
Potentiometer: Points of meassurement: (Position 3)
1.4 k Ω
Heating element: Voltage
220/ 230 V
Flow rates/ Inlet volume: Inlet valve
4 l/min
Accessory:
If you need spare parts apart from the spare
part list have a look in the
Service Bulletin 4812 718 40084.
Regeneration: Position 2
after wash cycles 7
Water hardness 11 - 15 °dh 1.9 - 2.7 mmol/l 19 - 27 °Fh
Fan for drying: Resistance
141 Ω
Water softener: Salt container
2 kg
Potentiometer: Points of meassurement: (Position 0)
0.0 k Ω
Options:
Zone washing
Electronic boards: Serial boards (CB programmed)
487001
Regeneration: Volume
300 cm 3
Drain pump motor: Voltage
220/ 240 V
Regeneration: Position 4
after wash cycles 3
Water hardness 22 - 28 °dh 3.8 - 5.0 mmol/l 38 - 50 °Fh
Spray arms, turning rhythm at alternating spray system: Final rinse
Spray arm lower ~2min
Upper arm ~2min
Detergent capacity: Dosage steps
1 ml - 6 ml
Electrical base data: Total power
2.0 kW - 2.2 kW
Potentiometer: Points of meassurement: (Position 4)
1.8 k Ω
Coil of dispenser: Frequency
50/ 60 Hz
Spray pump motor alternating spray system: Power Consumption
125 W
Dimensions + Weight: Product dimensions (Weight)
53 kg
Double electric water inlet valve: Voltage
220/ 240 V
Flow rates/ Inlet volume: Spray arm upper
~ 27 l/min
Heating element: Fuse
206 °C
Motor Diverter Valve: Frequency
50/ 60 Hz
Regeneration valve: Resistance
3.13 k Ω
Electronic boards: Serial boards ()
Programing of version and programmed control board, see "Service" and "Data set" on rating plate of inner door:
Data Energy Label: Energy Performance
A
Flow rates/ Inlet volume: Flow meter
208 lmp/l
Data Energy Label: Reference program
A5e
Размеры + Вес: Размеры продукта (ширина)
59.7 cm
Drain pump motor: Resistance
146 Ω
Succession of programs: Programs ()
see program diagram
Potentiometer: Points of meassurement: (Position 5)
2.3 k Ω
Spray pump motor alternating spray system: HI
79 Ω
Электрические базовые данные: частота
50 Hz
Spray arms, turning rhythm at alternating spray system: Prewash
Spray arm lower ~3min
Upper arm ~1min
Coil of dispenser: Voltage
220/ 240 V
NTC
20 °C 58.1 kΩ
25 °C 47.1 kΩ
30 °C 38.2 kΩ
40 °C 25.4 kΩ
50 °C 17.2 kΩ
60 °C 11.8 kΩ
70 °C 8.3 kΩ
80 °C 6 kΩ
85 °C 4 kΩ
Regeneration: Salt consumption for regeneration
77 g
Potentiometer: Points of meassurement: (Position 6)
2.6 k Ω
Электрическая база данных: Предохранитель
10 A
Spray pump motor alternating spray system: Voltage
220/ 240 V
Water pressure: Spray pump pressure
0.3 bar
Fan for drying: Voltage
220 V - 240 V
Размеры + Вес: Размеры продукта (Глубина)
55.5 cm
Regeneration: Position 1
after wash cycles 10
Water hardness 6 - 10 °dh 1 - 1.8 mmol/l 10 - 18 °Fh
Spray arms, turning rhythm at alternating spray system: Service Test program
Remark: When switching of the main switch or interrupt the mains during the Test Program runs, then the alternating of the spray arms change in the test program to the rhythm of main wash 5/3 min.
After finishing the test program (End LED shines and/or Start LED goes of) must the appliance be switched off.
Spray arm lower ~30sec
Upper arm ~30sec
Double electric water inlet valve: Frequency
50/ 60 Hz
Regeneration valve: Voltage
220/ 240 V
Potentiometer: Points of meassurement: (Position 1)
0.5 k Ω
Rotations: Fan for drying
2500 RPM
Detergent capacity: Main wash
40 cm 3
Spray arms, turning rhythm at alternating spray system: Main wash
Spray arm lower ~3min
Upper arm ~5min
Water softener: Regeneration dosage
300 cm 3
Heating element: Resistance
24.5 Ω
Water Volume: Water Volume Level
Regeneration 0.3 l 15 mm
Back rinse 3x 1.0 l 60 mm
Prewash 3.9 l 120 mm
Main wash 3.2 l 118 mm
Intermediate rinse 1 3.2 l 118 mm
Intermediate rinse 2 3.2 l 118 mm
Clear rinse 3.2 l 118 mm
Safety/ overflow 8.5 l 141 mm
Heating element: Heating speed
~ 2.0 °C/min
Double electric water inlet valve: Resistance
2.0 k Ω
Rotations: Spray arm lower
30 RPM - 40 RPM
Regeneration: Position 6
after wash cycles 1
Water hardness 36 - 60 °dh 6.4 - 10.7 mmol/l 64 - 107 °Fh
Spray pump motor alternating spray system: HA
60 Ω
Data Energy Label: Cleaning Performance
A
Potentiometer: Points of meassurement: ()
1(black) to 2 (middle)
Flow rates/ Inlet volume: Drain pump
16 l/min
Regeneration: Position 3
after wash cycles 5
Water hardness 16 - 21 °dh 2.8 - 3.7 mmol/l 28.37 °Fh